Can Faster Supplemental Screening Reduce Missed Breast Cancers in Women with Extremely Dense Breasts?
The original Dutch DENSE trial showed that adding full-protocol breast MRI after a negative mammogram reduced interval cancers in women with extremely dense breasts. However, population-based implementation remains constrained by cost, limited scanner capacity, long acquisition times, and modest patient uptake (59% in the original trial).
The DENSE-2 trial, launched in November 2024, is designed to show if contrast-enhanced mammography (CEM) or abbreviated MRI (AB-MRI) can significantly reduce interval cancer rates compared to standard screening mammography alone in women with extremely dense breasts and negative mammograms. In an accompanying Radiology editorial, Bahl emphasizes that supplemental screening must balance reductions in interval cancers against false-positive referrals, biopsies, patient burden, resource utilization, and cost. By evaluating AB-MRI (a ~5-minute scan) and CEM (utilizing existing mammography gantries), DENSE-2 addresses capacity constraints that preclude widespread implementation of full-protocol MRI.
Study Description
DENSE-2 (ClinicalTrials.gov: NCT06636370) is a multicenter randomized trial within the Dutch national screening program at 15 hospitals. The study will enroll 36,000 women aged 49–72 with extremely dense breasts and negative mammograms, randomized before consent to CEM, AB-MRI, or mammography alone (6000 to each of CEM or AB-MRI, with expected compliance of 59%, and 24,000 controls). As of April 3, 2026, 73% of target recruitment was completed. Full enrollment is expected in 2027.
The study design aims to avoid changes in screening behavior among women assigned to usual care. For women with extremely dense breasts, DENSE-2 will assess whether supplemental imaging reduces interval cancers diagnosed between screening rounds. It is designed to compare each test with mammography alone, not directly compare CEM with AB-MRI.
Women invited for supplemental screening can receive the same test across two biennial rounds. Trained radiologists interpret images using ACR BI-RADS lexicons for CEM and MRI. Dutch regulations prohibit BI-RADS 3 (“probably benign”) assessments.
The primary endpoint is the first-round interval cancer rate (invasive and in situ cancers per 1,000 screens) assessed via linkage with the Dutch National Cancer Registry and is expected to report results in 2031. Secondary endpoints include incremental cancer detection rate, false-positive rate, positive predictive value, stage distribution, adverse events, participant and provider experience surveys, focus groups, and long-term health economics modeled via Microsimulation Screening Analysis (MISCAN).